Microfocus X-ray Source G-311 D-series

Microfocus X-ray Source G-311 D-series

This is a microfocus X-ray source series specially for industrial X-ray non destructive inspection. These X-ray sources realize high speed imaging with high resolution by stable X-ray beam.

Microfocus X-ray Source G-311 D-series

CE

RoHSⅡ

Features

Pulse Exposure (G-311MH-DP)
  ・Low running cost of X-ray equipment (lengthen X-ray source and sensor life time)
  ・Low exposure of measuring objects

Low Tube Voltage Imaging (G-311ML-D)
  ・High contrast imaging of soft materials

High Power (G-311VH-D)
  ・High power and high throughput Imaging



<Series features>

  1. 110kV voltage ramp time within 1sec.
  2. Quick image acquisition
  3. Target maintenance free
  4. No need for target rotation
    Improving equipment operation ratio
  5. Warming-up within 3 min.
  6. Solution of the long waiting time at starting up X-ray equipment
    No need for tube aging after long term storage
  7. Self diagnosis of X-ray tube life time
  8. Scheduled maintenance of X-ray equipment
  9. 4μm resolution at 10watts
  10. High throughput Imaging and high magnification
  11. CE and RoHSⅡ compliant
  12. Applicable for overseas operation


♦Image examples

Bonding wire

Bonding wire (300x)

100kV 100µA (300x)

Flip chip

Flip chip (300x)

80kV 60µA (300x)

BGA

BGA (120x)

90kV 100µA (120x)

Tire

Tire (1x)

40kV 100µA (1x)

* High resolution date and photographing conditions of the images are available. Please inquire with this form.

Applications

Widely applicable for In-line / off-line X-ray non-destructive Inspection.


  • X-ray radioscopy
  • X-ray CT

Notice :

The X-ray sources were developed specifically for industrial use and can not be used for food and drinks or medical applications.

Specifications

Parameter Unit G-311MH-D G-311MH-DP G-311ML-D G-311VH-D
Maximum Power
Consumption
W 40 65
Operation Continuous, Pulse
Pulse Software
≧1sec
Hardware
≧50ms
Software
≧1sec
Minimum Resolution
(JIMA RT RC-02B)
µm 4 4 - 5 4 - 8
Tube Voltage
Operational Range
kV 60 - 110 40 - 110 60 - 110
Tube Current
Operational Range
(Target Current)
µA 10 - 100 10 - 300
Maximum Output W 10 30
Input Voltage (DC) V 24
Operational Ambient
Temperature
°C 10 - 45
Storage Temperature °C 0 - 50
Operational and
Storage Humidity
% ≤85 (No Condensation)
Weight kg 21 (incl. Inverter)
High Voltage Power
Supply
Built-in
X-ray Tube Sealed Transmission Type
X-ray Tube Cooling
Method
Forced Convection Cooling
X-ray Window
Material / Thickness
— / mm C (Diamond) / 0.29
Target Material W (Tungsten)
X-ray Beam Angle deg 168 (Max.), 80 (80%, Equidistance)
External Control RS-232C (External contact input is available with G-311MH-DP)

Dimensions

Microfocus X-ray Source G-311 D-series

Catalog Download PDF:1.38MB


Back to Page top